![slr5700 mototrbo cps software manual slr5700 mototrbo cps software manual](https://i.ytimg.com/vi/wVrBzNwv-TU/maxresdefault.jpg)
This is an input line that allows the repeater operator to monitor an analogue channel. Same as Major Alarm except this pin will change state when a minor alarm is detected. This would be connected to the Disable input of the standby repeater. Particularly useful if you are using the repeater in a hot-standby configuration. This output will change state when a major alarm is detected. This is applicable to Single Site Digital mode and Repeater configurations only. CWID will not be transmitted while this option line is active. This is an input line, that when activated, disables the receive and transmit operations of the repeater for as long as the pin is activated.
![slr5700 mototrbo cps software manual slr5700 mototrbo cps software manual](https://www.radiotronics.co.uk/blog/wp-content/uploads/2020/04/motorola-cps-2.0-logo-300x235.jpg)
![slr5700 mototrbo cps software manual slr5700 mototrbo cps software manual](https://4.bp.blogspot.com/-Cag10pGc6yY/VgIJlqUSHeI/AAAAAAAACSc/Zboa-Vz3LuE/s1600/FW_MOTOTRBO_R024000.png)
Debounce prevents accidental/incorrect activation of the input due to poor electrical contact so you should really use this if the input is originating from a relay or switch. If the GPIO pin is configured as an input (via the Feature selection), debounce can also be set. Active Level defines what the poutput or input level will/must be for a true condition. The Feature drop-down configures what input or output will be present on that pin.